Accredited testing laboratory for acoustic and noise measurements |
|
![]() ![]() |
|
English
We offer complex services in the area of building acoustics. We do both calculations and measurements:
Keywords: noise, environmental noise, noise measurements, sound insulation,air-borne sound insulation, structure-borne sound insulation, vibrations, room acoustics, reverbation time, building acoustics Contact us! Ing. Daniela Hroššová
|
|
DeutschWir bieten komplexe Leistungen im Bereich Bauakustik an. Wir führen sowohl Berechnungen als auch Messungen durch:
Stichworte: Lärm, Umgebungslärm, Lärmmessungen, Luftschalldämmung, Trittschalldämmung, Vibrationen, Raumakustik, Nachhallzeit, Gebädeakustik Kontaktieren Sie uns! Ing. Viktor Zwiener, Ph.D. DEKPROJEKT s.r.o.
|
|
List of selected references
|
|
| Savoy hotel, Prague
2010 Calculation of the apparent sound insulation index and |
![]() |
| Walmark a.s., Třinec
2010 The excessive noise transmission between meeting rooms in the company's headquarters WALMARK was to be solved. We performed measurements of acoustic insulation of dividing walls and a building survey aimed at finding the most important modes of transmission of noise. Finally we designed structural modifications leading to increase of sound insulation between meeting rooms. |
![]() |
|
Aquapalace Čestlice by Prague 2009 We dealt with room and structural acoustics in the phase of reprocessing of project documentation. The task was to verify the initial acoustic solutions in relation to current legislative requirements and propose adjustments reflecting changes in layout and in construction. The aim was to eliminate the adverse impact of noise from plant and facilities to the protected indoor and outdoor spaces of the building and to achieve the desired properties of the selected internal spaces in terms of room acoustics. |
|
|
Augustine hotel, Prague A luxury Augustine hotel is located near Lesser Town Square in Prague in the former monastery complex of buildings. High demands on the acoustic comfort of clients are a matter of course. Measuring tests of sound insulation between rooms and of the spread of noise into the protected areas in the interior were performed before passing the bulding to use. |
![]() |
|
NH hoteles, Olomouc We calculated the reverberation time and proposed a concept of acoustic design of a congress hall. Requirements on the reverberation time are mandatory according to the Government Decree 148/2006 and the compliance is proven according to the Czech technical standard ČSN 73 0527. |
![]() |
|
Miura hotel, Čeladná We created a room acoustics study for a specific designhotel near a golf resort in Beskydy mountains. |
|
|
Hotel Hermitage (Park Inn), Prague We created a room acoustics study of a congress hall. |
![]() |